How to Bill for HCPCS Code E1592 

## Definition

Healthcare Common Procedure Coding System (HCPCS) code E1592 refers to an “Oxygen concentrator, adjustable for portable or stationary use.” This device can supply oxygen both at home and while the patient is in transit, providing a continuous or pulse dose of oxygen as per medical needs. Oxygen concentrators covered under this HCPCS code must be adjustable to serve in both portable and stationary environments without requiring separate devices.

The primary purpose of this oxygen concentrator is to deliver concentrated oxygen for patients who experience chronic respiratory conditions that impede their ability to process air normally. The E1592 code is utilized in medical billing, including insurance claims, for the provision of such dual-purpose devices to patients. Given its versatility, this type of concentrator is integral to the long-term management of oxygen delivery in patients with chronic conditions such as chronic obstructive pulmonary disease, emphysema, or pulmonary fibrosis.

For billing purposes, this code falls under the broader category of durable medical equipment (DME). Devices covered under HCPCS code E1592 are typically considered appropriate for individuals requiring more flexible oxygen delivery options due to their active lifestyles or specific medical needs. The code anticipates that the described concentrator is for long-term use, which differentiates it from devices intended for short-term or temporary relief.

## Clinical Context

Oxygen concentrators provide supplemental oxygen primarily to patients with respiratory illnesses who demonstrate insufficient oxygenation as confirmed by medical testing. Clinical conditions commonly associated with the use of an adjustable oxygen concentrator include chronic obstructive pulmonary disease, severe asthma, and interstitial lung disease, among others.

By offering both portable and stationary support, the concentrator allows patients greater mobility and autonomy in managing their medical conditions. In some cases, these patients may require oxygen both while seated or lying down, as well as during routine activities outside their homes or while traveling. This ensures consistent oxygenation and prevents desaturation episodes, reducing associated risks such as hypoxemia.

Healthcare providers often prescribe oxygen concentrators after evaluating the patient’s oxygen saturation levels through pulse oximetry or arterial blood gas analysis. To qualify for insurance reimbursement, clinicians may be required to demonstrate that the patient’s oxygen desaturation cannot be adequately managed by less sophisticated methods (e.g., intermittent oxygen therapy or stationary-only devices).

## Common Modifiers

Modifiers are used in conjunction with HCPCS code E1592 to provide additional details about the billing circumstances for the oxygen concentrator. Some commonly used modifiers include modifier “RR,” indicating that the device is being rented rather than purchased, and modifier “UE,” which signifies that the equipment is being purchased as a used item rather than new.

Another relevant modifier is “KX.” This modifier clarifies that the patient meets the specific medical necessity criteria stipulated by Medicare for the use of the oxygen concentrator, meaning the provider has documented sufficient evidence, such as blood gas or oxygen saturation levels, to warrant insurance coverage.

Other common modifiers include “GA” (advance beneficiary notice on file) and “GZ” (no advance beneficiary notice on file). These modifiers relate to whether the patient has been notified in advance that Medicare might not cover the equipment and whether documentation was provided properly.

## Documentation Requirements

Detailed and accurate documentation is essential in order to justify the use of code E1592 for an oxygen concentrator. Providers must include thorough patient assessments that detail the patient’s primary respiratory diagnosis and the specific testing that confirms hypoxemia or oxygen desaturation. Typical tests include pulse oximetry or arterial blood gas results, which demonstrate the need for long-term oxygen therapy.

In addition to diagnostic evidence, the provider must include a prescription that outlines the need for both continuous and/or pulse oxygen delivery. The prescription must indicate whether the patient requires oxygen delivery during rest, activity, and/or sleep, confirming the necessity for a device that functions both as a stationary and portable oxygen concentrator. Furthermore, the provider should clearly document that the patient has failed to achieve adequate oxygenation via other treatment methods or equipment.

Healthcare entities are responsible for maintaining records of the oxygen concentrator settings, the daily use expectations, and any follow-up evaluations that affirm the patient’s ongoing dependence on supplemental oxygen. This clear and comprehensive documentation is critical to ensuring that claims using the HCPCS code E1592 are accepted and reimbursed by insurance providers.

## Common Denial Reasons

Insurance claims utilizing HCPCS code E1592 may be denied for several reasons. A frequent denial reason is the failure to provide adequate documentation, particularly related to the patient’s oxygen saturation levels or the medical necessity for a portable, as opposed to stationary-only, oxygen concentrator. Without definitive testing results or a clear, detailed prescription, claims are likely to be rejected.

Another common cause for denials stems from incomplete or incorrect use of modifiers. For example, if a provider does not apply the “KX” modifier when required to demonstrate medical necessity, or misapplies rental vs. purchase modifiers, the insurance claim may not be processed correctly. Similarly, failure to include appropriate modifiers to designate whether the equipment is new vs. used can lead to claim rejections.

Lastly, claims may be denied if they are submitted after the timeline allowed by the insurer or if prior authorization was not obtained. Many insurance companies, including Medicare, require prior authorization for durable medical equipment, particularly when it involves more complex technologies like oxygen concentrators.

## Special Considerations for Commercial Insurers

While Medicare guidelines are often followed by commercial insurance companies, there may be slight variances in coverage criteria and policies for HCPCS code E1592. Some insurers may require more rigorous documentation of the trial and failure of less expensive oxygen delivery methods before covering an adjustable concentrator. Others may impose stricter usage guidelines or request frequent revalidation of the medical necessity through follow-up examinations.

Commercial insurers may also differ regarding rental versus purchase options. Whereas Medicare often requires the equipment to be rented initially before any purchase option is considered, certain commercial insurers may allow outright purchases. Providers should verify specific policies with each insurance carrier to ensure the appropriate code and associated modifiers are applied.

Providers should also be vigilant about state-specific regulations that commercial insurers might follow. State laws governing durable medical equipment billing can differ, adding another layer of complexity to the reimbursement process for adjustable oxygen concentrators.

## Similar Codes

Several HCPCS codes exist that share similarities with E1592, though these codes typically describe devices with more specialized or limited roles. For example, HCPCS code E1390 relates to a stationary oxygen concentrator but does not include portable functionality. This code would be billed in cases where patients solely require oxygen therapy at home and not during activities outside.

In contrast, HCPCS code E1392 is used for portable oxygen concentrators but without the stationary capability. This code is apt for patients who are mobile but do not require continuous oxygen while stationary, making it more appropriate for those with specific and less-severe oxygenation needs.

Other comparable codes include E0431, which pertains to portable gaseous oxygen systems that deliver oxygen but without the electronic concentrator technology. These devices lack the multi-function adaptability provided by the dual-use device described by E1592 and are often used in different clinical scenarios where portability alone is essential. Providers must select the appropriate code based on the specific medical equipment supplied and the patient’s clinical needs.